Photobeam 5000
3
Installation
Prior to installing the devices, please review the installation considerations below:
–
–
–
–
–
–
–
–
–
–
3.1
Beam spread
The beam spread angle is ±0.7 °from the transmitter to the receiver. Refer to the diagram and
table below to determine the installation conditions.
1
Figure 3.1: Beam distance and spread
Callout ﹘ Description
1 ー Transmitter
2 ー Horizontal spread (B)
3 ー Vertical spread (C)
Bosch Security Systems, Inc.
Install in an area that is clear of objects
Install the transmitter/receiver within the maximum protection range of the model
Do not install:
–
Receivers into intense sources of light (for example, rising and setting sun)
–
On movable surfaces subject to vibrations
–
Detectors where immersion to water, corrosive liquids, or exposure to high levels of
dust can occur
–
Detectors in close proximity to strong electromagnetic noises
Do not use detectors with other photobeam detectors or receivers
Do not stack detectors
Do not disassemble or modify this detector
Do not install while the power is on
Avoid extreme temperature and humidity ranges as defined in the products specifications
Avoid installing detectors near magnets and/or magnetized materials
Avoid beam interference between other units when multiple units are installed.
Installation and Operation Guide
5
Callout ﹘ Description
4 ー Receiver
5 ー Distance (A)
Installation | en
9
2
3
4
2016.02 | 03 | F.01U.305.910
Need help?