Installing the Surveillance cabinet

3.1

Pre-installation checklist

1.
2.
3.
4.
Caution!
Select a rigid mounting location to prevent too much vibration to the camera.
!
Warning!
Install external interconnecting cables in accordance to NEC, ANSI/NFPA70 (for US
application) and Canadian Electrical Code, Part I, CSA C22.1 (for CAN application) and in
!
accordance to local country codes for all other countries.
Branch circuit protection incorporating a 20 A, 2-pole Listed Circuit Breaker or Branch
Rated Fuses are required as part of the building installation. A readily accessible 2-pole
disconnect device with a contact separation of at least 3 mm must be incorporated.
3.2

Mounting the Surveillance cabinet

Before you mount the unit, decide if you route the wires through the holes in the bottom or
in the back of the unit. If you choose the holes in the back, move the 2 seal plugs to the
holes in the bottom before you mount the unit.
Use 20 mm (3/4 inch) NPS fittings for the holes on the bottom and back of the unit. Use 15
mm (1/2-inch) NPS fittings for the side holes.
1.
2.
Warning!
A stud diameter of 6.4 mm (1/4 inch) to 8 mm (5/16 inch) able to withstand a 120 kg (265
!
lb) pull-out force is recommended. The mounting material must be able to withstand this
pull out force. For example, 19 mm (3/4 inch) minimum for plywood.
3.
4.
5.
Bosch Security System
Make sure that you have the correct camera and accessories for the installation in your
environment.
Determine the location and distance for the unit based on its voltage and current
consumption. Prepare the wires and connections that are necessary to connect your
camera.
You can route the main power supply through an intermediate unit (type PA1 or PA2)
before connecting the power to a PA0 type unit. Refer to Cable and wire standards for
wiring information and distances. See also Routing power through intermediate unit.
Use only UL listed liquid tight strain reliefs for conduits to the unit to ensure that water
cannot enter the unit. Use water tight conduits and fittings to meet NEMA 4 standards.
Use the wall mount template supplied with the unit to locate the 4 mounting holes for
the unit.
Drill holes for the 4 mounting anchors. For outdoor installation, use a weatherproof
sealant around each hole at the mounting surface.
Place the unit into the optional Trim Skirt.
Mount the unit to the mounting surface.
For a Wall installation: Use 4 corrosion-resistant, stainless steel studs (not
supplied). Then proceed to Step 6 below.