MONITOR INDICATION ON PROJECTOR
• Two monitor indicator lamps provided on the top of the projector signal the abnormal conditions
inside it. (See the illustration at right.)
• After the power plug is inserted into the receptacle, pressing
projector's rear and
lamp in red to indicate that the projector is on standby.
• While the projector is on standby, pressing "POWER" button will light up the power indicator lamp in
green, and the light source lamp will light up.
• Press POWER while the lamp is on and select OFF on the confirmation screen, the power monitor
indicator lamp blinks in orange letting the lamp cool for about 2 minutes, which follows that the
power monitor lamp lights up in red resulting in a standby state.
• In the case of a trouble, the power, temperature/lamp indicator lamps lights up or blinks, and the
monitors shut off the power automatically. Take the following measures.
Monitor indication
The power indicator lamp lights
up in red, and the temperature/
lamp indicator lamp blinks in
red.
The power indicator lamp and
temperature/lam indicator lamp
light up in red.
The power indicator lamp
blinks in red and green, and the
temperature/lamp indicator
lamp turns off.
Lighting
up
Note
• While the light source lamp is cooled, do not pull out the power plug from the receptacle, as this may cause damage to the projector as well as shorten
the life of the lamp.
Downloaded From projector-manual.com Fujitsu Manuals
/I on the left hand side of AV selector's front will light up the power indicator
Abnormal condition
The temperature inside the
projector has risen to an
extraordinary level.
The light source lamp will not
light up.
Abnormal operation of the
projector.
The monitor indication as shown on the left figure indicates to light up in red and green, to blink in
red and green, and to turn off.
Blinking Turned
off
/I on the right hand side of the
Measures to take
If the ventilation openings are blocked with foreign matters,
remove them and re-install the projector so that proper ventilation
is maintained. Check the air filters and lamp protection filter for
accumulation of dust. If they are soiled, clean them or replace
them with new ones (see page E-54). If the abnormal condition
persists despite the above measures, call your dealer for service.
Leave the projector untouched for 2minutes, and then, restart the
projection. By doing so, the cooling fan rotates for approximately
1 minute to cool the inside of the projector. If the abnormal
condition persists despite the above measures, call your dealer for
service.
If the rotation of the cooling fan is blocked by any foreign matters,
remove them. Pull out the power plug from the receptacle, and
leave the projector untouched until its inside cools down. Then,
turn on the power of the projector again. If the abnormal condition
persists despite the above measures, call your dealer for service.
Monitor indicator lamps on the