Site Requirements - Page 6
Supplied By www.heating spares.co Tel. 0161 620 6677
Existing Chimneys
A chimney which has previously been used to burn solid fuel
MUST be swept before beginning the installation and any
restrictions such as dampers or register plates must be
removed. The chimney must be at least 3.10m (10ft) in
height and also meet the following requirements:
1)
It must not be cracked.
2)
It must serve one room only.
3)
It must not be joined with any void, space or any
room other than that in which the fire is fitted.
4)
It must not be blocked by paper or rubble etc.
5)
It must have a positive flue pull up the chimney.
6)
It must have a standard 229mm x 229mm (9in x
9in) section or a 127mm(5in) flue liner.
If there is no positive airflow up the chimney DO NOT FIT
THE FIRE. Seek expert advice before continuing with the
installation. A positive flue pull can be detected by holding a
lighted match or taper near to the fireplace opening.
PRE-CAST FLUES
The fire is suitable for fitting into properly designed and
constructed pre-cast flues, complying with BS 1289. The flue
must be at least 3.10m (10ft) in height and have a flue way
of at least 197mm x 67mm (7¾in x 2
cross-sectional area.
NOTE: It is important to ensure that the mortar between
the blocks has not been forced into the flue way. If there
is mortar in the flue way, then it must be removed. If
raking blocks are used, they must be fitted according to
the manufacturer's instructions.
Gas Supply
The gas installation should be in accordance with BS 6891.
The connection to the appliance is Rc¼ (¼in BSPT internal)
and is located at the centre (rear) of the fire, permanently
fixed to the bottom of the back plate. Ensure that the
pipework from the meter to the appliance is of adequate
size. Do not use pipes of a smaller diameter than the
appliance gas connection.
Electrical Supply
THIS APPLIANCE MUST BE EARTHED The mains supply
required is 230V ~ 50Hz fused at 3A.
NOTE: The method of connection to the electricity
supply must facilitate complete electrical isolation of the
appliance, preferably by the use of a fused three pin
plug and unswitched shuttered socket outlet, both
complying with the requirements of BS 1363.
Alternatively, connection may be made via a fused
double-pole isolator with a contact separation of at least
1
3mm (
/
in) in all poles and serving the appliance only.
8
6
5
/
in) or equivalent
8