Baxi Arena Super Installation And Servicing Instructions page 19

Gas burner
Table of Contents

Advertisement

Annual Servicing - Page 19
Cleaning the Burner / Injectors
Remove the burner as follows:
Remove the locating pins (these also secure the burner to its
support brackets).
Disconnect the compression nuts from the injectors. Remove
the burner from the fire.
Using a soft brush remove any dirt or debris from the top of
the burner and ensure that the ports and aeration openings
are free from obstruction.
Release and remove the injectors from the burner. Examine
and clean carefully then replace with the flat end of the
injector in the burner.
BEFORE RE-ASSEMBLING ALL COMPONENTS
Examine the glass frame, if the glass is in any way
damaged, then it must be replaced.
NOTE: This is a heat resistant glass and must not be
replaced by "ordinary" glass.
The glass may be cleaned with a cream cleansing agent if
required.
Examine the glass frame sealing rope on the fire and replace
it if in any way damaged.
Examine the coal bed and replace it if any major damage
has occurred.
Re-assemble all components in reverse order, ensuring that
the flue spigot is engaged into the hole in the closure plate.
Make good all gas and electrical connections and check for
gas soundness.
Recommission the fire before use, then re-assemble the
outer components in the reverse order of dismantling.
19
Supplied By www.heating spares.co Tel. 0161 620 6677