Electrode Lead

1. Remove the insulating sleeve from the body of the
electrode. Disconnect the electrode lead from the electrode.
2. Disconnect the electrode lead from the spark generator.
Undo the screw holding the orange panel to the chassis. Lift
the panel upwards and withdraw the sleeve and lead.
Thread the new electrode lead through the insulating sleeve.
Fit the new electrode lead to the spark generator and
electrode.
Re-assemble the components in the reverse order to
dismantling.

Spark Generator

Remove the front screw holding the spark generator in
place, and release the rear screw, enabling the generator to
be removed. Disconnect the electrical connections and
electrode lead.
Fit the new spark generator and re-assemble all components
in the reverse order to dismantling.

Resistor

Remove the two screws securing the light shield bracket.
Unclip the resistor from the side frame.
Disconnect the two resistor wires from terminal strip.
Replace resistor and refit in reverse order.
25
Supplied By www.heating spares.co Tel. 0161 620 6677