Control Tap and Micro-Switch

Remove the control knob by pulling from the spindle.
Remove the two screws holding the bezel in place.
Disconnect the two electrical connections from the light
switch, taking note of their orientation. Remove the bezel.
Release the thermocouple from the control tap by
unscrewing the retaining nut.
Disconnect the two electrical connections from the micro
switch.
Release the nut-and-olive connections on the control tap
body and disconnect the bundy tubing from the control tap.
Disconnect the gas inlet at the control tap by releasing the
compression fitting.
Release the locknut fixing the control tap to the chassis.
Access to the locknut may be gained through the bezel
location.
Withdraw the control tap from the fire.
At this point change the micro-switch if required by removing
the circlip holding it in position on the control tap.
Fit the new micro-switch or the new control tap in reverse
order.
Make good all gas and electrical connections. Temporarily
reconnect electricity supply. Light the fire, turn off the
electricity supply and check all joints for gas soundness.
Turn the fire off. Re-assemble all components in reverse
order to dismantling.