Changing Components - Page 26
Pilot, Electrode & Thermocouple Assy
Note: The thermocouple cannot be changed as an individual
component. The complete assembly must be changed in the
event of one or other component failure(s).
1. Remove the lead from the electrode.
2. Undo the pilot feed pipe from the assembly.
4. Undo the thermocouple from the gas tap.
3. Remove the screws holding the pilot assembly bracket to
the fire chassis. Unclip the thermocouple from the fire
chassis. Withdraw the pilot assembly and bracket.
Remove the screw holding the assembly to the bracket.
Re-assemble all components in the reverse order to
dismantling.
Electro-Magnetic Unit
4. Release the thermocouple from the control tap by
unscrewing the retaining nut.
5. Release the Electro-Magnetic Unit retaining nut and
remove the unit from the control tap.
Fit the new Electro-Magnetic Unit and replace the retaining
nut.
Fix the thermocouple in position taking care not to
overtighten the retaining nut. Re-assemble all components in
reverse order to dismantling.
26
Supplied By www.heating spares.co Tel. 0161 620 6677