Replacement Of Fuses; Strobe Wizard Plus Transmitter; Regular Check; Return To Customer Service - Hensel Pro Mini 1200AS User Manual

Power pack
Table of Contents

Advertisement

Available languages

Available languages

HENSEL Studiotechnik

Replacement of fuses

In case of a broken fuse replace fuses only, when the unit is
switched off and separated from lamp heads and charging
units. Only use fuses with the required value (10A quick, 10AF).
Fuses for Flash Heads:
300W Halogen lamp
650W Halogen lamp
Attention:
Never repair or bridge fuses. Only use fuses according to IEC
127-2/1 and EN 60127-2/1, respectively (ceramic tube).
Strobe Wizard Plus
The HENSEL radio transmitter Strobe Wizard Plus is almost
maintenance-free. Because of the low energy consumption a
battery lifetime of 1 to 2 years can be assumed depending on
the degree of utilization. The battery can be exchanged by
resolving the screw 30 at the bottom of the unit. This provides
access to the electronics and the battery can be removed from
the clips and exchanged. Before reinstallation of the new
battery the polarity must be observed. The positive pole
should be pointed towards the Power Down button 23.

Regular check

National safety regulations require regular inspection and
maintenance of electrical systems and appliances. Power packs
and accessories must be regularly checked for safe operation.
Yearly inspection of the appliances serves the safety of the user
and protects your investment in the system.

Return to customer service

To achieve a maximum protection of the unit sending it in for
service, the original packaging should be kept.
9

Disposal

Packaging of the power pack has to be separately disposed of
and recycled. Worn out and broken appliances has to be
disposed off by electronics recycling.
User Manual Pro Mini 1200 AS Power Pack
Ue = 230 V
2 AF quick
4 AF quick
Ue = 115 V
4 AF flink
-----
39

Advertisement

Chapters

Table of Contents
loading

Table of Contents