Flash Power Control - Hensel Pro Mini 1200AS User Manual

Power pack
Table of Contents

Advertisement

Available languages

Available languages

8:
Dial for precise flash
power setting
5, 11:
LED-Displays
HENSEL Studiotechnik
In case of connecting 2 flash heads per channel, the maximum
power provided by the power pack for each channel (600J) is
distributed symmetrically over the connected heads (300J per
flash head).

Flash power control

Each of both switches 20 and 22 allows a maximum flash
power reduction of 450J. A further 2 f-stop reduction in 1/10
increments can be achieved using dial 8. This covers a range of
5 f-stops for symmetrical operation (1200J to 38J)and 4 f-stops
for asymmetrical operation (600J to 38J).
The flash output is shown on the two digits 7-segment display 5
for symmetrical operation, and on both LED Displays 5 and 11
separately for each channel in case of asymmetrical operation
(see table 1 and 2).
Tab.1: Symmetrical operation (A
with 1 flash head on channel A or B
Switch 20
1/1
1/1
1/1
1/2
1/2
1/4
Tab.2: Asymmetrical operation (A
with 1 flash head per channel
Switch 20
1/1
1/2
1/4
*:
power output displayed on the LED and
output range adjustable using dial 8
User Manual Pro Mini 1200 AS Power Pack
+
Switch 22
LED*
1/1
10 – 8.0
1/2
9.5 – 7.5
1/4
9.3 – 7.3
1/2
9.0 – 7.0
1/4
8.5 – 6.5
1/4
8.0 – 6.0
Switch 22
LED*
1/1
9.0 – 7.0
1/2
8.0 – 6.0
1/4
7.0 – 5.0
B)
Power (J)
1200 - 300
900 - 225
750 - 188
600 - 150
450 - 113
300 - 75
B)
Power (J)
600 - 150
300 - 75
150 - 38
35