User Manual Pro Mini 1200 AS Power Pack
READY
FC
AUDIO
10:
LAMP
10:
FULL
PROP
7:
FC
36

Flash readiness

Flash readiness of the power pack is shown by
READY control lamp 12 turns on (green light)
Modeling lamp turns on when Flash Check mode is
activated (switch 7)
Acoustical signal, when AUDIO 6 is switched on.

APD system

In case of reducing the flash power, the stored energy will be
discharged by APD-system (Automatic Power Drop). No flash
will be triggered. After switching off power packs will be
automatically discharged.

Modeling lamp

The modeling light is turned on and off, respectively, using
LAMP switch 10. Turning on of the modeling lamp will be only
effective, if the modeling lamp of the connected flash head is
switched on.
FULL/PROP
When switch 10 is set to „FULL" position, the maximum output
of the modeling lamp is achieved.
To have proportionality between modeling lamp and flash
power output switch 10 has to be set to „PROP.
The mode of operation is indicated by the control LED.
If there is no light at the control LED the modelling lamp is
switched off.
Dim Mode
The dim mode is intended to prolong the life span of the
modeling lamp. If the modeling lamp level is adjusted to FULL
or to PROP between 10. 0 and 9.1, the output is automatically
dimmed by approximately 1 f-stop after stopping working with
the flash unit for longer than 35 minutes (default value).
Pressing any button you like switches the modeling light to the
previously adjusted undimmed level. If required, this default
value can be changed by entering a value from 5 minutes up to
95 minutes. For doing this, press dial 8 to enter a new value
shown on display 5. Wait for 3 seconds and the display
changes to the flash power setting.
Flash Check
If this mode is switched on using switch 7 (LED indicator lights
up), then the modeling lamp is turned off after a flash and is
turned on after recharging to the adjusted power level. This
shows correct charge as well as readiness to flash.
The flash check mode guarantees that the flash heads have
triggered when more than one flash unit is used.