Configuration
a port. DGS-1210-08P/24P will auto disable the ports if port current is over 375mA in 802.3af mode or
625mA in pre-802.3at mode.
From Port/To Port: Specifies the PoE function of a port or ports.
State: Select "Enabled" or "Disabled" to configure PoE function for designated port(s). Default is Enabled.
Time Range: Select the PoE time profile configured from Time Range Settings to enable the time-based
PoE function on designated port(s). Default setting is N/A.
Priority: Configure the power supply priority as "Low", "Normal", or "High" on designated port(s). Default is
Normal.
Power Limit: This function allows you to manually set the port power current limitation to be given to the PD.
To protect the DGS-1210-08P/24P and the connected devices, the power limit function will disable the PoE
function of the port when the power is overloaded. Select from "Class 1", "Class 2", "Class 3", "Class 4"
(DGS-1210-24P only) and "Auto" for the power limit. "Auto" will negotiate and follow the classification from
the PD power current based on the 802.3at standard.
User Define: Check the box and input the power budget (from 1 to 30W for the DGS-1210-24P or 1 to
15.4W for the DGS-1210-08P) to manually assign an upper limit of port power budget on designated port(s).
Click Apply to make the configurations take effects or click Refresh to redisplay the table.
SNMP > SNMP > SNMP Global Settings
Simple Network Management Protocol (SNMP) is an OSI Layer 7 (Application Layer) protocol designed
specifically for managing and monitoring network devices. SNMP enables network management stations to
read and modify the settings of gateways, routers, switches, and other network devices. Use SNMP to
configure system features for proper operation, monitor performance and detect potential problems in the
Switch or LAN.
Managed devices that support SNMP include software (referred to as an agent), which runs locally on the
device. A defined set of variables (managed objects) is maintained by the SNMP agent and used to manage
the device. These objects are defined in a Management Information Base (MIB), which provides a standard
Note: The PoE Status information of Power
current, Power Voltage, and Current is the power
usage information of the connected PD; please
"Refresh" to renew the information.
Figure 4.110 – PoE > PoE Port Setting
Note: For the PoE Port Settings table, if the
classification was shown as "Legacy PD", it will be
classified to non-AF PD or Legacy PD.