COMPONENT TESTING INFORMATION
Continuity is indicated as 100Ω and below. Each pad must be press to perform the following test.
Element Cycle
Relay drive requirements are as a percentage of on time based on a 60 second cycle.
Bake
First rise = 100% bake, 50% broil, then 100% bake, 25% broil.
Broil
0% bake, 100% broil
Clean
Stage 1 - 100% broil, 0% bake, for 15 minutes.
Stage 2 - 25% broil, 100% bake.
Convection
First rise = 100% bake, 50% broil, then 100% convection element and 100% convection fan*.
Convection bake
Same as bake plus 100% convection fan*.
Convection broil
Same as broil plus 100% convection fan*.
*- Convection fan is de-energized when the oven door is opened.
33