Advertisement

INSTALLATION INSTRUCTIONS

HB0133
IU600ES SERIES
INTENDED FOR DOMESTIC COOKING ONLY
!
!

READ AND SAVE THESE INSTRUCTIONS

INSTALLER: LEAVE THIS MANUAL WITH HOMEOWNER.
HOMEOWNER: USE AND CARE INFORMATION
ON PAGES 10
12.
TO
Venmar Ventilation ULC, 550 Lemire Blvd., Drummondville QC J2C 7W9
1-800-567-3855
REGISTER YOUR PRODUCT ONLINE AT: www.bnv.ca
For additional information, visit
www.venmar.ca
21224 rev. 04

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ISPIRA IU600ES SERIES and is the answer not in the manual?

Questions and answers

Summary of Contents for Venmar ISPIRA IU600ES SERIES

  • Page 1: Installation Instructions

    READ AND SAVE THESE INSTRUCTIONS INSTALLER: LEAVE THIS MANUAL WITH HOMEOWNER. HOMEOWNER: USE AND CARE INFORMATION ON PAGES 10 Venmar Ventilation ULC, 550 Lemire Blvd., Drummondville QC J2C 7W9 1-800-567-3855 REGISTER YOUR PRODUCT ONLINE AT: www.bnv.ca For additional information, visit www.venmar.ca...
  • Page 2 WARNING WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC TO REDUCE THE RISK OF INJURY TO SHOCK OR INJURY TO PERSONS, OBSERVE PERSONS IN THE EVENT OF A RANGE TOP THE FOLLOWING: GREASE FIRE, OBSERVE THE FOLLOWING*: 1. Use this unit only in the manner intended 1.
  • Page 3: Table Of Contents

    TABLE OF CONTENTS ....................3-4 NSTALL DUCTWORK 2. P ..................... 4-5 REPARE INSTALLATION 3. P ....................5-6 REPARE THE HOOD 4. I ) ................ 6 NSTALL GLASS PANEL WG MODELS ONLY 5. I ..................7-8 NSTALL THE ADAPTER DAMPER 6. I ......................
  • Page 4: Install Ductwork

    INSTALL DUCTWORK (CONT'D) 80% E AXIMUM ENGHTS ECOMMENDED TO CHIEVE XHAUST EFFICIENCY 3 ¼” 10” M 6” AXIMUM ROUND AXIMUM OOF OR WALL CAP LBOW (90° 45°) ENGHT ENGHT WITH DAMPER 1” TANDARD ELBOWS WITH INTERNAL RADIUS 2. PREPARE INSTALLATION WARNING When performing installation, servicing or cleaning the unit, it is recommended to wear safety glasses and gloves.
  • Page 5: Prepare The Hood

    2. PREPARE INSTALLATION ( CONT Cut-out the openings for duct (A) and power cable (B), in cabinet or wall, according to the direction of discharge chosen. See figures below. ORIZONTAL DISCHARGE ERTICAL DISCHARGE CABINET BOTTOM 1½’’ 1/4’’ 3½’’ 2’’ 5¼’’ 5¼’’...
  • Page 6: Nstall Glass Panel

    3. PREPARE THE HOOD ( CONT 3.3 Using both hands, gently pull on the blower wheel to remove. Set blower wheel aside. HO0243 4. INSTALL GLASS PANEL ( WG MODELS ONLY The WG hood models decorative glass panel is sold separately and has to be installed before completing the hood installation.
  • Page 7 5. INSTALL THE ADAPTER/DAMPER ( ALL MODELS The wall duct must be roughed-in to properly interface with the hood. Before performing the installation, make sure the adapter fits easily in the duct. If this hood replaces an existing hood, please note that location of the air exhaust can vary from one manufacturer to another. ORIZONTAL ISCHARGE CREW LOCATIONS...
  • Page 8: Install The Hood

    5. INSTALL THE ADAPTER/DAMPER ( ALL MODELS CONT IVOT Using two no. 6 x 1/2’’ screws provided, secure the adapter/damper to the back of the hood. Remove tape from damper flap. HO0178 OTTOM Seal the adapter/damper to the hood using metal foil duct tape. ERTICAL ISCHARGE IVOT...
  • Page 9: Connect Wiring

    CONNECT WIRING WARNING Risk of electric shock. Electrical wiring must be done by qualified personnel in accordance with all applicable codes and standards. Before connecting wires, switch power off at service panel and lock service disconnecting means to prevent power to be switched on accidentally.
  • Page 10: Led Lighting

    9. REINSTALL THE HYBRID FILTERS CAUTION Remove protective plastic film covering filters before reinstalling them. Rest rear filters edge on filter springs in the range hood. Tilt up the filters into position. Make sure filter tabs are securely engaged in range hood front edge slots after installation.
  • Page 11: Care

    11. CARE ( CONT LASS PANEL Hot water with mild soap or glass cleaner is all that is usually needed. When using mild soap, rinse with clear water. Wipe dry with a clean, soft cloth to avoid water marks. Avoid when choosing a detergent: - Any cleaners that contain bleach.
  • Page 12 12. OPERATION ( CONT C. M ON/OFF: ASTER When blower is off, press this button to turn the hood on to the last memorized speed level. If there is no memorized speed level, speed will be set at level 1. To turn off the blower and the light simultaneously, press this button once.
  • Page 13: Wiring Diagram

    13. WIRING DIAGRAM WARNING Risk of electric shock. Electrical wiring must be done by qualified personnel in accordance with all applicable codes and standards. Before connecting wires, switch power off at service panel and lock service disconnecting means to prevent power from being switched on accidentally.
  • Page 14: Service Parts

    14. SERVICE PARTS HL0224...
  • Page 15: Damper

    ARTS AND EPAIRS In order to ensure your unit remains in good working condition, you must use Venmar Ventilation ULC genuine replacement parts only. Venmar Ventilation ULC genuine replacement parts are specially designed for each unit and are manufactured to comply with all the applicable certification standards and maintain a high standard of safety.
  • Page 16: W Arranty

    To contact Venmar Ventilation ULC warranty service, call 1-800-567-3855 in Canada. In order to qualify for a warranty claim, the owner of a Venmar Ispira IU600ES Series range hood must have the model and serial number along with a proof of the original purchase date. At the time of requesting service, describe the nature of any defect in the product or part.

Table of Contents

Save PDF