INSTALLATION INSTRUCTIONS HRV 2600* HR 2.6* VB0064 NOTES: 1. HRV 2600* and HR 2.6* models are available in Canada only. 2. HEPA 4100* model is available in United States only. *Patents pending READ AND SAVE THESE INSTRUCTIONS INSTALLER: LEAVE THIS MANUAL WITH THE HOMEOWNER. HOMEOWNER: USE AND CARE INFORMATION ON PAGES 18 TO 21.
Page 2
If a duct has to be connected to the furnace return plenum, it must be connected not closer than 9’ 10” (3 m) from this plenum connection to the furnace. 6. The ductwork is intended to be installed in compliance with all local and national codes that are applicable. WARNING CAUTION Exclusively for HRV and HEPA Models: Venmar Ventilation inc. 1-800-567-3855 - 2 -...
1. TYPICAL INSTALLATIONS Installations may vary according to the model number and the position in which the unit is installed. Use the following illustrations as guidelines to help you decide on how your unit will be installed. All the units should be hung from the joists, and installed either vertically or horizontally. NOTE: For more details, see Point 5.2 in Section 5 INSTALL THE UNIT.
1. TYPICAL INSTALLATIONS 1.2 I HEPA 4100 O NSTALLATION FOR 1.2.2 HEPA 4100 A TTIC NSTALLATION All 3 types of installations can be used in the attic (Stand Alone, Central Draw Point or Return-Return). The example shown below is a Return-Return installation (connection to a forced air system).
2.1 HRV 2600 HR 2.6 U NITS 30.2'' (767 mm) 22.9'' (581 mm) VK0049A FRONT VIEW 2.3 M OUNTING AND ERVICING ONSIDERATIONS • The two following pictures are showing the minimum clearance needed to open the door completely. VD0117 NOTE: A minimum of 8” (203 mm) clearance from any obstruction on top of the unit is required for the ductwork radius turn. •...
3. BEFORE STARTING 3.1 I NSPECT THE ONTENTS OF THE To avoid risk of suffocation, discard the plastic bag wrapping the unit and the wall control. • Inspect the exterior of the unit for shipping damage. Ensure that there is no damage to the door, door latches, main switch, etc. •...
4. WALL CONTROL INSTALLATION Always disconnect the unit before making any connections. Failure in disconnecting power could result in electrical shock or damage of the wall control or electronic module inside the unit. Failure to comply with the following can cause erratic operation of the unit: •...
Page 10
4. WALL CONTROL INSTALLATION 7. Turn the unit switch knob to OFF position in order to unlock the door. Unlatch the door and open it. If required, the door can be removed. To do so, remove the stopper (A) located on the right side of the door hinge.
5.2 H OW TO ANG THE Use the 4 chains and springs in the hardware pack provided with the unit. According to your needs, you can install the unit either in vertical or horizontal position. VD0074 • Insert the 4 hooks in the square holes and assemble them to the unit using 4 screws #8 - 32 x 3/4”. •...
5. INSTALL THE UNIT (CONT’D) 5.3 P LANNING OF THE UCTWORK All units in this manual are prebalanced. • Keep it simple. Plan for a minimum of bends and joints. • Keep the length of outside insulated duct to a minimum. •...
5. INSTALL THE UNIT (CONT’D) 5.4 I NSTALLING NSULATED 5.4.1 S TAND LONE YSTEM LL UNITS How to connect the flexible duct to the unit ports • Using the colored sticker dot included, identify which duct it is (red dot for stale airflow and blue dot for filtered airflow). Repeat the procedure for the other register (or diffuser).
5. INSTALL THE UNIT (CONT’D) 5.4 I NSTALLING NSULATED 5.4.2 C ENTRAL DRAW OINT Fresh/Filtered air ductwork (Return side connection) (cont’d) HEPA 3100, HF 3.1 HEPA 4100 • Fix the duct connector to the forced air unit duct using its 4 retaining screws (#8 x 3/4” long). Seal with duct tape.
5. INSTALL THE UNIT (CONT’D) 5.5 I NSTALLING NSULATED LEXIBLE Make sure the vapor barrier on the insulated ducts does not tear during installation. Use the following procedure for connecting the insulated flexible ducts to the Tandem® transition* ( EXHAUST AIR TO OUTSIDE and FRESH AIR FROM OUTSIDE ).
5.5 I NSTALLING NSULATED LEXIBLE 5.5.2 C 5’’ ONNECTION TO THE Avoid compressing the insulation when you pull the tape tightly around the joint. Compressed insulation loses its insulation properties and causes water dripping due to condensation on the exterior surface of the duct. 4.
5. INSTALL THE UNIT (CONT’D) 5.6 I NSTALLING XTERIOR 5.6.3 C ONNECTING ANDEM 2. Join the end of the Tandem transition to the rear of the exterior backplate. Secure with 2 Xmas tree pins and seal properly with duct tape. The exterior backplate must be installed with the word “TOP’’...
6. CONTROLS 6.1 M WITCH All units are equipped with a 3-position main switch, located on the front panel. OFF: NIT IS OFF AND DOOR IS UNLOCKED 6.2 40415 40425 W ONTROLS The included wall control is 40415 (intented for HRV 2600, HEPA 3100 and HEPA 4100 units only) or 40425 control (intented for HR 2.6 and HF 3.1 units only).
6. CONTROLS (CONT’D) 6.4 W ONTROLS ONFIGURATION See the configuration table below for the list of configuration parameters. Press the Menu button for 3 seconds to enter or exit the configuration menu. NOTE: The wall control automatically saves any changes and exits the configuration menu if no button is pressed within the next 60 seconds.
7. MAINTENANCE Risk of electrical shocks. Before performing any maintenance or servicing, always disconnect the unit from its power source. 7.1 B IANNUAL AINTENANCE ESSENTIAL Perform this maintenance when the Filter Maintenance LED is flashing. Follow these steps: Turn switch knob to OFF to unlock the door. Unlatch the door and open it.
7. MAINTENANCE (CONT’D) 7.1 B IANNUAL AINTENANCE ESSENTIAL Wash the 2 core filters under hot water with mild soap. Rinse thoroughly and let dry completely before reinstalling on the core. Remove the dust on the core using a vacuum cleaner with a soft brush attachment.