CH temp. for corr. factor
Mode type
Manual Tch
Room temp. sensor
CH temp. sensor
Permanent pump
estyma electronics
www.estyma.pl
Service
Central heating temperature correction
required the desired room temperature for 1 º
C. For example, if the correction factor is set
at 6 ° C, room temperature set at 20 ° C and
measured in the room is 20.5 ° C then the
temperature calculated at will be reduced by
3 ° C.
Specifies the input mode central heating
temperature:
manual - the temperature of central heating
inflicted manually,
weather - the temperature of central heating
calculated from the heating curve.
The desired temperature of central heating
when the mode is set to manual.
Specifies whether the system uses a room
sensor.
Specifies whether the system uses a sensor
heating.
Yes - the pump runs at a given temperature
in the room, reduced the temperature for
heating (only with the use of a sensor for
central heating and room sensor),
No - after reaching the set temperature in the
room the pump is turned off.