Service - Estyma iGNEO COMPACT User Manual

Boiler controller
Table of Contents

Advertisement

6 Main menu

6.1.5 Service

WARNING !!! Access the service is intended only for qualified technical personnel. The
changes may cause malfunction of the system.
Function
Comf. MAX pump temp.
Econ. MAX pump temp.
MIN Tch pump
Source
Temperature MAX
Mixer time
Hot water priority
Pump test
Mixer test
Circ. name
CH temp. for -20°C
CH temp. for 0°C
CH temp. for 10°C
page 26
PL20110629
Service
Maximum outdoor temperature at which the
circulating pump can work in a comfortable
range.
Maximum outdoor temperature at which the
circulating pump can work in a economic
range.
Minimum temperature calculated for central
heating at which the circulating pump can be
operated.
Specifies the source of energy for central
heating circuit.
Maximum temperature for central heating.
Time of full opening of the mixer.
Priority for hot water of the heating circuit.
During heating hot water the central heating
pump is not working.
Starts the pump regardless of other
conditions.
Starts the mixer motor independently of the
other conditions.
Gives name for the central heating circuit.
The point of the heating curve for -20 ° C.
The point of the heating curve for 0 ° C.
The point of the heating curve at 10 ° C.