Time Zone Restricted" Access Code Programming; Delete An Access Code (Simple And Time Zone Restricted); Delete All Access Codes For The Same Type Of Device (Simple And Time Zone Restricted) - DKS 1812 Access Plus Installation & Owner's Manual

Pc programmable residential telephone intercom/access control system
Hide thumbs Also See for 1812 Access Plus:
Table of Contents

Advertisement

2.6.4 "Time Zone Restricted" Access Code Programming

This programming sequence programs access codes into the system memory with time zone restrictions applied. It also
allows programming of the access codes to momentarily activate a relay or to hold open (latch) a relay.
Note: Up to 50 access codes can be programmed into the system. This 50 includes "simple" access codes programmed in
2.6.1 AND "time zone restricted" access codes programmed in 2.6.4. For example, if 10 "simple" access codes are
programmed in 2.6.1, then only 40 "time zone restricted" access codes can be programmed in 2.6.4.

2.6.5 Delete an Access Code (Simple and Time Zone Restricted)

This programming sequence deletes individual "simple" and "time zone restricted" access codes that have been
programmed into the system.
2.6.6 Delete All Access Codes for the Same Type of Device (Simple and TZR)
This programming sequence deletes ALL existing "simple" and "time zone restricted (TZR)" access codes for the same
type of device. To delete ALL existing "simple" and "time zone restricted" access codes, this programming sequence will
need to be preformed for each type of device that is connected to the system.
WARNING: Once started, all "simple" and "time zone restricted" access codes for the same type of device will be erased.
1812-162-V-5-16
1. Press
7 0 and enter the MASTER CODE. [
*
2. Enter the device type (0 = card, 1 = transmitter, 2 = keypad, 3 = other), then press
3. Choose and enter a five-digit access code, then press
4. Enter a minimum of 1, and a maximum of 4 time zones (valid time zones are 0 through 6) that you
want to apply to this access code, then press
Time zone 0 - Always deny access.
Time zone 1 - Allows 24/7 access for relay 1 and any additional relays.
Time zone 2 - Allows 24/7 access for relay 2 and any additional relays.
Time zones 3, 4, 5 and 6 - Are time zones that have been programmed in 2.7.6.
5. Enter 0
for momentary relay activation or enter 1
*
6. Repeat steps 2 through 5 to program additional access codes (Time zone restricted).
7. Press 0 # TOGETHER to end. [0 # (beeeeeep)]
1. Press
7 1 and enter the MASTER CODE. [
*
2. Enter the device type (0 = card, 1 = transmitter, 2 = keypad, 3 = other), then press
3. Enter the five-digit device access code to be deleted, then press
See 2.6.1 and/or 2.6.4 for the five-digit access code.
4. Repeat steps 2 and 3 to delete additional existing "simple" and "time zone restricted" access codes.
5. Press 0 # TOGETHER to end. [0 # (beeeeeep)]
1. Press
7 2 and enter the MASTER CODE. [
*
2. Enter the device type (0 = card, 1 = transmitter, 2 = keypad, 3 = other), then press
3. Press 9 9 9 9, then press
4. The programming sequence will end itself automatically. [beeeeeep]
7 0 _ _ _ _ (beep)]
*
. [ _ _ _ _
*
*
7 1 _ _ _ _ (beep)]
*
7 2 _ _ _ _ (beep)]
*
. [ 9 9 9 9 (beep)]
*
. [ _ _ _ _ _
(beep)]
*
*
(beep)]
*
to hold open (latch) the relay. [ _
. [ _ _ _ _ _
(beep)]
*
*
. [ _
(beep)]
*
*
(beep)]
*
. [ _
(beep)]
*
*
. [ _
(beep)]
*
*
37

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

1812 access plus

Table of Contents