Sub-Net Mask (Reboot Required); Set The Gateway (Router) Ip Address (Reboot Required); Set The Port Number (Reboot Required) - DKS 1812 Access Plus Installation & Owner's Manual

Pc programmable residential telephone intercom/access control system
Hide thumbs Also See for 1812 Access Plus:
Table of Contents

Advertisement

2.3.3 Sub-Net Mask
Factory setting is: 255.255.255.000
All sub-net mask should be set to 255.255.255.000. This rarely needs to be changed, consult with your network expert
first. Valid values for any of the three digit numbers is 000 to 255.
4 4
5 5
6 6
7 7
8 8
9 9
0 0
System Keypad
2.3.4 Set the Gateway (Router) IP Address
Factory setting is: 192.168.001.001
If the 1812 is connected directly to the computer with a crossover cable, then this address must be set to 000.000.000.000.
If the 1812 is connected to the computer through a router, then set this value to the router's IP address. Valid value for any
of the three digit numbers is 000 to 255. (See pages 23 and 24 for network configurations and addresses)
4 4
5 5
6 6
7 7
8 8
9 9
0 0
System Keypad
2.3.5 Set the Port Number
Factory setting is: 01030
This must be the same port number that was programmed in the software. Valid values are 01024 to 65535.
All 5 digits must be entered in the field, for example: 1030 must be entered as 01030
4 4
5 5
6 6
7 7
8 8
9 9
0 0
System Keypad
If you are OR are going to use a computer with the 1812 Access Plus, NO other programming at the System
Keypad is required. All programming parameters beyond this point can be set in the Management software.
This software will show all the specific programming parameters that will exist in the memory of the 1812 after it has been
programmed. It can be easily recalled for future modification or re-programming.
4 4
5 5
6 6
7 7
8 8
9 9
0 0
1812-162-V-5-16
(reboot required)
1. Press
5 2 and enter the MASTER CODE. [
*
2. Enter the sub-net mask number. Use the
[ _ _ _
(beep) _ _ _
*
*
3. Press 0 # TOGETHER to end. [0 # (beeeeeep)]
1. Press
5 3 and enter the MASTER CODE. [
*
2. Enter the gateway (router) IP address. Use the
[ _ _ _
(beep) _ _ _
*
*
3. Press 0 # TOGETHER to end. [0 # (beeeeeep)]
1. Press
5 6 and enter the MASTER CODE. [
*
2. Enter the port number, then press
3. Press 0 # TOGETHER to end. [0 # (beeeeeep)]
The system keypad DOES NOT have the capability to show any of the programming that will exist
in the memory of the 1812 after being programmed. The only way to keep track of the specific
parameters that have been programmed into the 1812 for future reference when NOT using the
management software, is to physically write down all the information in a log (In back of manual).
5 2 _ _ _ _ (beep)]
*
key to enter the "dot".
*
(beep) _ _ _
(beep) _ _ _
*
5 3 _ _ _ _ (beep)]
*
key to enter the "dot".
*
(beep) _ _ _
(beep) _ _ _
*
(reboot required)
5 6 _ _ _ _ (beep)]
*
. [ _ _ _ _ _
(beep)]
*
*
STOP!
PC's only, NOT for use with MACs
(beep)]
*
(reboot required)
(beep)]
*
29

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

1812 access plus

Table of Contents