2.3 Programming the Network Setup for a Computer

Before proceeding with any of the programming steps in this section, install the 1812 Management software on the computer
(PC ONLY) that will be used for this purpose. Be sure that the computer has a network card installed, or a modem installed in it
(or connected to it) depending on which connection method will be used. Once the software is installed and the 1812 is
connected, refer to the software programming steps and help screen instructions to proceed with the programming steps in this
section. The system keypad may be used to program the computer's network setup in this section but can be a little tedious to
use.
Be sure that SW1 is in the ON position (MODEM/TCP ENB) on the Access Plus Interface Board.
1970-010
1970-010
J1
J1
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
9
9
10
10
11
11
12
12
13
13
14
14
Reboot Note: If a programming step calls for a reboot, follow the programming steps in 2.3.1. If you are performing several
15
programming steps that call for a reboot, complete ALL of those steps first, then perform the reboot sequence in 2.3.1.
16
Important Note: The 1812 will prompt you with short tones (beep) when each programming step has been correctly keyed
17
in and with a long tone (beeeeeep) when all of the programming steps have been successfully completed in the sequence.
18

2.3.1 Enable / Disable TCP / IP Support - System Reboot

Factory setting is: 0 (TCP / IP Disabled)
This programming sequence enables or disables the support for TCP / IP. It will also cause an automatic reboot of the 1812
two seconds after the programming sequence is completed. For this reason, perform this step after all other network setup
programming sequences have been completed (2.3.2 through 2.3.5) or whenever an individual network programming step
is performed.
1. Press
2. Press 0
4 4
5 5
6 6
7 7
8 8
9 9
0 0
System Keypad
3. The system will reboot automatically.
Once the 1812 is connected, the green LED on the RJ-45 jack on the interface board should light indicating that a good wire
connection has been made (See illustration above). The LAN DOWN LED should go off after a few seconds if all previous
programming steps have been completed and programmed successfully.
2.3.2 Set the 1812 IP Address
Factory setting is: 192.168.001.030
This must be set to the same address that was programmed in the software. A valid value for any of the three digit fields in
this sequence is 000 to 255. (See pages 23 and 24 for network configurations and addresses)
All 3 digits MUST be entered in each field between dots, for example: 192.168.1.30 must be entered as 192.168.001.030
1. Press
2. Enter the IP address. Use the
4 4
5 5
6 6
7 7
8 8
9 9
0 0
System Keypad
3. Press 0 # TOGETHER to end. [0 # (beeeeeep)]
28
J4
1
2
3
4
5
6
7
8
5 0 and enter the MASTER CODE. [
*
to disable TCP / IP OR press 1
*
5 1 and enter the MASTER CODE. [
*
[ _ _ _
(beep) _ _ _
(beep) _ _ _
*
*
RS-485 RX
TERMINATION
LAN DOWN
BAD DNS
SW2
LAN
CONNECTION
DATA TRANSMIT
J1
J1
J1
J1
J1
J1
J1
J1
1
1
RJ-45
Jack
(Cat5)
Cat5 Cable
5 0 _ _ _ _ (beep)]
*
to enable TCP / IP. [ _
*
(reboot required)
5 1 _ _ _ _ (beep)]
*
key to enter the "dot".
*
(beep) _ _ _
(beep)]
*
*
MODEM / TCP ENB
SW1
PHONE LINE
1972-010
J3 J3
J3
1970-010
J2
1 2 3 4 5 6 7 8 910
(beep)]
*
M
MASTER
MASTER
ER
CODE
CODE
DE
IN USE
MIC VOL
MIC VOL
SPEAKER
VOL
11
1812-162-V-5-16

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

1812 access plus

Table of Contents