Before You Start Programming: IMPORTANT! Make sure the 1812 has power and we strongly suggest that you become
familiar with these programming instructions before beginning any programming of the 1812 Access Plus system.
The 1812 has been programmed at the factory with many of the programming parameters already set (default setting) for a
typical residential application with a single 1812. There is no need to reprogram these parameters unless you want to change
them. For easy reference, refer to the chart on page 31 that list the various programming functions and their default settings.

2.1 Programming the Master Code

This programming step sets the system MASTER CODE. The master code is the four-digit number required to gain access to
the system memory.
The 1812 comes from the factory WITHOUT a master code programmed into it.
The Master Code can ONLY be programmed from the system keypad.
Step 1. Open the cabinet of the 1812 and press the master code button (See below). The Blinking LED right above the
button will remain ON.
Note: After you press the master code push button, the blinking LED will stay ON indicating that you are in
the master code programming sequence. If a master code is not entered within 10 seconds, the master code
program sequence will automatically end and the LED will return to a blinking state indicating that you have
exited the master code programming sequence.
Step 2. Enter a four-digit master code then press
Actual keystrokes used on system keypad:
4 4
5 5
6 6
7 7
8 8
9 9
0 0
System Keypad
Same keystrokes as written in this manual: [ _ _ _ _
Multiple 1812 Master Codes Note: The master code number is used to distinguish each 1812 when
multiple 1812s are connected together. They CAN NOT function together with duplicate master codes.
Step 3. The LED will revert to Blinking. Close the cabinet.
J1
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
OV
Programming Documentation Note: There are programming log sheets in the back of this manual to document your specific
master code, and keep track of all other programming that is preformed to this 1812 Access Plus. Keep this with all other system
documentation for future reference. There is no way of retrieving the master code after it has been programmed in. If you
forget it, you will have to program in a new one but all other previously programmed information will remain intact.
26

SECTION 2 - PROGRAMMING

.
*
J4
1
2
3
4
SW2
5
6
LAN CONNECTION
7
8
You MUST program a MASTER CODE.
System Keypad
4 4
5 5
6 6
7 7
8 8
9 9
0 0
any four numbers
? ?
? ?
? ?
? ?
Then
(beep)]
*
You should write down your master code, see note below.
RS-485 RX
LAN DOWN
BAD DNS
SW1
MODEM / TCP ENB
DATA TRANSMIT
J1
RJ-45
Connector
(Cat5)
1972-010
J3
KEYPAD
1 2 3 4 5 6 7 8 910
"BEEP"
Master Code
LED
MASTER
CODE
Master Code
PHONE LINE
IN USE
Push Button
MIC VOL
SPEAKER
1970-010
VOL
J2
11
1812-162-V-5-16

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

1812 access plus

Table of Contents