If the procedures above do not resolve the problem:
1. Perform steps 1 through 3 of the pre-installation instructions listed in Chapter 4.
2. Remove the left-side cover as described in Chapter 4.
3. Lay the server on its side (components showing) for better access to the DIMM slots.
4. If necessary, remove any accessory boards or cables that prevent access to the DIMM
slots.
5. Locate the DIMM slots.
6. Reseat the memory modules.
7. Observe the post-installation procedures described in Chapter 4.
8. Verify that all memory is validated during POST.
If the problem still persists:
1. Perform steps 1 through 5 mentioned above.
2. Remove all but one memory module.
3. Perform steps 7 through 8 mentioned above.
If the error is not present:
1. Power off and unplug the server then add another memory module, continuing this
process until all the modules are installed, or until a failure occurs.
2. Verify the failure by reinstalling the module by itself and attempt to duplicate the error.
3. Try the faulty module in another memory slot to confirm that the slot is not defective.
4. Replace the defective module.
For detailed procedures on how to remove and install memory modules, go to the "Memory"
section in Chapter 4.
HP ProLiant ML110 Server Operations and Maintenance Guide
System Maintenance
6-19