Checking the Engine-Oil Level

Before you start the engine and use the machine, check
the oil level in the engine crankcase; refer to
Engine-Oil Level (page
38).

Checking the Cooling System

Before you start the engine and use the machine, check the
cooling system; refer to
Checking the Cooling System (page
44).
Checking the Hydraulic
System
Before you start the engine and use the machine, check the
hydraulic system; refer to
Hoses (page
49).

Filling the Fuel Tank

Recommended Fuel
Use only clean, fresh diesel fuel or biodiesel fuels with low
(<500 ppm) or ultra low (<15 ppm) sulfur content. The
minimum cetane rating should be 40. Purchase fuel in
quantities that can be used within 180 days to ensure fuel
freshness.
Fuel tank capacity: 53 L (14 US gallons)
Use summer grade diesel fuel (No. 2-D) at temperatures
above -7° C (20° F)and winter grade (No. 1-D or No.
1-D/2-D blend) below that temperature. Use of winter grade
fuel at lower temperatures provides lower flash point and
cold flow characteristics which will ease starting and reduce
fuel filter plugging.
Use of summer grade fuel above -7° C (20° F) will contribute
toward longer fuel pump life and increased power compared
to winter grade fuel.
Important: Do not use kerosene or gasoline instead of
diesel fuel. Failure to observe this caution will damage
the engine.
Biodiesel Ready
This machine can also use a biodiesel blended fuel of up
to B20 (20% biodiesel, 80% petrodiesel). The petrodiesel
portion should be low or ultra low sulfur. Observe the
following precautions:
The biodiesel portion of the fuel must meet specification
ASTM D6751 or EN14214.
The blended fuel composition should meet ASTM D975
or EN590.
Checking the
Checking the Hydraulic Lines and
Painted surfaces may be damaged by biodiesel blends.
Use B5 (biodiesel content of 5%) or lesser blends in cold
weather.
Monitor seals, hoses, gaskets in contact with fuel as they
may be degraded over time.
Fuel filter plugging may be expected for a time after
converting to biodiesel blended.
Contact your distributor if you wish for more information
on biodiesel.