Installation Method; Drainage Method - Sinclair AMC-14Aa MOBILE SERIES User Manual

Table of Contents

Advertisement

ACCESSORIES OF DRAINAGE WATER

Installation method

Drainage
When using COOL and DRY, condensate would be gathered in flume. When
method:
flume filled, buzzer would sound for 8 times and LCD displays error code H8.
The whole unit would stop working till water filled removed and resume running
after compressor had stopped for 3 min. Take out the cap on drainage hose, take
out the hose from fixing clip and drain out water in the flume. After drainage, put
the cap on hose to present water leakage, and fix drainage hose on fixing clip.
Important:
Drain the water only if the unit shuts down with display error code "H8"
(Full water tank) or drain the water only if the unit is going to be
turned off for long period of time. If you drain the water constantly,
during normal operation, the unit could be damaged.
Note:
Do install drainage hose before turning on the unit to prevent water
●  
from making floor and carpet dirty.
The L drainage cap taken from drainage point should be stored well for future use.
●  
1. Take out L drainage cap from drainage point at chassis.
2. Install drainage cap on drainage hose, and it should be inserted tightly without loosing.
3. Fix fixing clip for drainage hose at rear plate by bolts.
A
4. Insert one end of drainage hose to drainage point to the end and assembly
pipe clip to prevent water leakage.
5. Fix drainage hose at fixing clip.
A
B
C
A
B
A. Drain port
B . Drain cap
B
A. Drain port
B . Attach drain hose clip with screw provided.
D
A. Drain plug
E
B . Drain port
C . Drain hose
-22-
D. C lamps
E . Drain hose clip