Service Diagnostics and Procedures
Control Board Diagnosis

Broil Relay (Inner and Outer)

When a broil element is selected, voltage is sent
to the broil relay coils. A red LED (D25 and D27) in
front of the respective relay verifies coil voltage is
being sent to that particular relay. This means that
12 VDC is being sent to the relay coil. It does not
indicate that the relay contacts are closing. When
the individual element relays are energized, power
(L1-black) is sent through the relay to the broil
elements. Power (L2-red) is supplied from the line
break relay).

Inner Broil Relay

Select a cooking program. When the inner relay
contact is energized (D25 LED at base of relay
illuminates red), check for 240 VAC between the
yellow wire at the line break relay and the violet
wire on P6. If 0 VAC is measured, disconnect power
and remove the P6 Molex plug.
Reconnect power
and using an Ohm
meter, check for
continuity between
the two relay
contacts. When the
relay is energized;
if you read infinite
ohms (
) this
Ω
indicates a bad relay
and replacement
of the control board is necessary. If 0 ohms are
measured, the relay contact is closing.

Outer Broil Relay

Select a cooking program. When the outer relay
contact is energized (D27 LED at base of relay
illuminates red),
check for 240 VAC
between the yellow
wire at the line
break relay and the
gray wire on P6. If
0 VAC is measured,
disconnect power
and remove P6
Molex plug.
Reconnect power
and using an Ohm
meter, check for continuity between the two relay
contacts. When the relay is energized; if infinite
© 2010 Viking Preferred Service
Place meter
leads here
LED
Place meter
leads here
ohms (
) are measured this indicates a bad relay
Ω
and replacement of the control board is necessary.
If 0 ohms are measured, the relay contact is closing.

Convection Element

Locate the P2 connector and the line break relay on
control board. The P2 connector will have a Molex
plug containing a white/red and black wire. The
white/red wire goes to the convection element and
the black wire is L1 input from main power supply.
P-2
Line Break Relay
With the power off and Molex connector removed
from the P2 control board connection, use an
Ohm meter to measure resistance between the
LED
white/red wire in the Molex plug and the yellow
wire at the line break relay. This will measure the
resistance of the convection element and should be
approximately 34.4
resistance, remove element to repair or replace as
necessary (see Convection Element Disassembly,
page 52).
P-2
Line Break Relay
. If the element fails to read
Ω
33