Service Procedures
Bake and Broil Solenoids
The bake and broil solenoids provide a means to open the gas valve. When the
DSI module receives 120 VAC input, the voltage is stepped down to 8 to
18 VDC and output to the appropriate bake or broil solenoid. This voltage is
sufficient to open the gas valve and allow gas to flow to the burner.
NOTE: The solenoids are sized for special voltage and current. DO NOT use
voltage above 8 to 18 VDC to operate the solenoids.
To access the bake and broil solenoids, remove the unit form installation and
remove the rear cover. The bake and broil solenoids are located on the right
hand side when viewed from the rear. The ower solenoid is for bake and the
upper solenoid is for broil.
Test Procedures –
Bake and Broil Solenoids
1.
Remove power to the unit.
2.
Set the Volt-Ohm meter to read resistance.
3.
Measure resistance at bake solenoid terminals.
4.
The Volt-Ohm meter should read 215 ohms +/- 30 ohms.
22
©2012 Viking Preferred Service