3.2

Installation location requirements:

The heater can be installed both on the exterior and interior.
Installation on exterior
The installation location must satisfy the following requirements:
■ There is sufficient space for the unit (see „3.3 Heater dimensi-
ons").
■ The installation location is protected from mechanical damage.
■ The installation location is protected from splash water and wa-
ter spray wherever possible.
■ The installation location is above the maximum permissible for-
ding level of the vehicle.
■ The combustion air inlet and exhaust gas outlet are separate (to
avoid exhaust crossover).
Installation on interior
The installation location must satisfy the following requirements:
■ There is sufficient space for the unit (see „3.3 Heater dimensi-
ons").
■ The connections for the combustion air system and the exhaust
system are completely on the outside.
■ The installation location is protected from mechanical damage.
■ Persons cannot come in contact with hot surfaces. Install con-
tact guard if necessary.
■ Heat-sensitive parts are protected from high temperatures. Ins-
tall heat shield if necessary.