Ap-7562 Grounding Post - Motorola AP-7562 Installation Manual

Table of Contents

Advertisement

Installation Guide

1.10.4 AP-7562 Grounding Post

The grounding post is located on the bottom of the Access Point above the GND symbol.
WARNING!
The grounding cable can be attached to the unit using one of the following methods:
• Use a grounding screw to securely attach the grounding cable to the grounding post. Use an 8mm socket
and driver to tighten the grounding screw to 30 inch pounds (lbf-in).
• Attach a ring lug to the grounding cable and use a grounding screw to securely attach the ring lug to the
Access Point. Use an 8mm socket and driver to tighten the grounding screw to 30 inch pounds (lbf-in).
The grounding cable for an AP-7562 must be at a minimum a #10 gauge wire cross
section.