3. With the Access Point positioned so the gore vent is facing down, insert the two M6 hex flange screws
in the bottom holes on the sides of the Access Point bracket into the open slot connections on the bottom
of the angle adapter bracket. Rotate the Access Point bracket upward and align the top holes on the sides
with the top holes on the angle adapter bracket. Insert two M6 hex flange screws into the top holes on
the angle adapter bracket.
4. Use a torque wrench or a ratchet and a 10mm socket, or an adjustable wrench, to finish attaching the
angle adapter bracket to the Access Point bracket with the four M6 hex flange screws in the open slot
connections and the top holes on the angle adapter bracket. Do not tighten the screws until all rotation
and tilt adjustments are complete.
5. To adjust the position of the Access Point, rotate the Access Point bracket (plus or minus 15 degrees) and
tilt the angle adapter bracket (up to 45 degrees).
6. Use a torque wrench or a ratchet and a 10mm socket, or an adjustable wrench, to tighten all screws when
all adjustments are complete.
7. Tighten all hex flange screws to 60 inch pounds (lbf-in).
To use the extension arm with the mounting hardware kit:
1. With the open slot connections facing down, attach the angle adjust bracket at the desired mounting
location using four #10/32 lag bolts.
2. Complete the steps for assembling and positioning the angle adapter bracket and Access Point bracket
sections outlined above. See
3. With the Access Point positioned so the gore vent is facing down, attach the extension arm to the Access
Point bracket with two ½ inch bolts and nuts. Tighten bolts to 300 inch pounds (lbf-in).
Vertical Pole Mount on page 26
.