Indications On The Display; Manual Operation Mode; Function Modes - Cardin Elettronica 101/SL402409 Instruction Manual

Automation for sliding gates with a dc powered motor
Hide thumbs Also See for 101/SL402409:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 13
INDICATIONS ON THE DISPLAY (D1)
Alarm indications
Both travel limits have cut in
The letter , will appear on the display and the system remains blocked.
The warning lights will flash for a three second period which is repeated
every six seconds. The only way to solve this problem is to check the
travel limits for obstacles or damage and then restart the system.
reset and the programmer will consider the gate to be completely
closed. It will not therefore accept closing commands.
Parameters loaded from EEPROM are wrong
The letter
, will flash on the display and the system remains blocked.
The only way to solve this situation is to enter the program mode and
reprogram the system. If the problem persists after reprogramming,
the problem regards the EEPROM (incorrect memorising). Switch off
the power to the system, after a few seconds switch it back on and
then reprogram the system.
Time programming mode block
( caused by: TB, FTCI, FTCS )
Function indications
defining the system configuration
waiting period between successive
programming stages
deceleration time setting (value 1)
level 1 electrical input sensor
work time programming
opening stage
block
reclosing pause (only if enabled)
closing stage
updating the electrical input monitoring system

MANUAL OPERATION MODE

This can be used to close the gate (or open it) under the direct control of the
operator (in this mode the electrical input monitoring system is excluded. The
aim of this command is to make installation easier and to allow you to have
the gate completely closed before starting the programming procedure. In this
mode the Led "L3" (marked "UPL") will remain lit.
This is obtained by pressing the button "SEL".
The motor will block in the closing direction due to:
- releasing the "SEL" button (takes you out of the "manual mode").
- activating the blocking button "TB" or the FTCI/FTCS safety devices: to
move the gate again you must first release the "SEL" button and then press
it again.
- activating the closing direction travel limit (if installed): pressing the "SEL"
button will not cause the gate to close, but it will switch the courtesy light
on.
This is obtained by pressing the button "SEL", and then the "PROG" button
straight away.
The motor will block in the opening direction due to:
- releasing both buttons (takes you out of the "manual operation mode").
- activating the blocking button "TB" or the FTCI/FTCS safety devices: to
move the gate again you must first release both buttons and then press
them again.
- activating the opening direction travel limit.
If the gate is closing: to enable an opening manoeuvre:
- press the "PROG" button
If the gate is opening: to enable a closing manoeuvre:
- release the "PROG" button
The courtesy light remains on all the time while in the "manual operation
mode"; it also lights up when an opening or closing command is given but
the travel limit blocks the command.

FUNCTION MODES

1) Automatic
Selected by enabling automatic reclosing (programming step 2, number
flashing). When the gate is completely closed the opening command will start
a complete cycle which will end with automatic reclosing and the courtesy
light switching off.
Automatic reclosing starts after the programmed pause period has elapsed
when the opening cycle has been completed or straight away after the inter-
vention of a photoelectric cell (the intervention of a photoelectric cell causes
the pause time to be reset).
During the pause time the symbol
blocking button during this period will stop automatic reclosing and conse-
quently stop the display from flashing.
The intervention of mechanical travel limits will block the gate.
The indicator light remains lit until the closing manoeuvre has terminated.
Note: The courtesy light switches on automatically each time a movement
command is given either by control button or by radio. The intervention of a
photoelectric cell during reclosing has no effect on the timing of the courtesy
light.
2) Semiautomatic
Selected by disabling automatic reclosing (programming step 2, number
flashing).
Work cycle control using separate opening and closing commands. When the
gate has reached the completely open position the system will wait until it
receives a closing command either via an external control button or via radio
control, before completing the cycle.
The activation of one of the opening travel limit causes the gate to stop and the
termination of the opening. Starting from the end of the opening manoeuvre
the courtesy light will switch off after the set period has elapsed. The indicator
light remains lit if the gate is not completely closed.
Limited opening command function
The management of the limited opening command "TAL" is similar to the
"TD" command.
number "1" fixed) activating the "TAL" button will start the limited opening
stage (only from the completely closed position) but while the gate is open-
ing pressing the button again will have no effect. Once the opening position
has been reached pressing the "TAL" button will start closing after which
pressing "TAL" again will have no effect.
step 1; number "1" flashing) activating the "TAL" button will start the lim-
ited opening stage (only from the completely closed position) pressing the
button again will block the gate; pressing the button a third time will start
the closing cycle. Pressing the "TAL" button again will have no effect.
ing command will become a full opening command.
If the FTCI photocell cuts in during the closing stage you will only have
partial movement in the opening direction.
When the system is operating off battery power the "TAL" command will be
interpreted as a complete opening command (like "TA").
Note: If you use the second radio channel function for the limited opening
command (binding posts 7 and 8) you could operate both the "TD" and
"TAL" functions from a two channel transmitter.
"TA" command
The "TA" command is operative even if the gate is opening or completely open.
It will hold the gate in pause while the "TA" button is pressed down (clock mode).
When the "TA" button is released the pause time will start after which automatic
reclosing will occur. Pressing the "TB" button during the reclosing pause will
block the reclosing function but you need only press a "TC" or "TD" command
at this point (even using a radio control) to go back to the clock mode.
17
will flash on the display and pressing the
TD" button (programming step 1;
TD" button (programming
not
-

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents