Cardin Elettronica BL1924ASW Manual page 19

Automation for hinged gates
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 17
Terminal board connections
7
CMN common for all inputs and outputs.
8
ELS electric lock output (fed continuously) 12 Vdc - 15 W.
9-10 LC-CH2 Potential free contact for the activation of the courtesy light (separate
power supply Vmax=30 Vac/dc: Imax=1A) or the second radio channel.
11
CMN common for all inputs and outputs.
12
LP 24 Vdc 25 W output for warning lights
intermittent activation (50%), 12,5 W continuous activation.
13
LS 24 Vdc 3 W output for an indicator light.
14
CMN common for all inputs and outputs.
15
30 Vdc controlled output, powering external loads
16
CMN common for all inputs and outputs.
17
30 Vdc output, powering external loads
18
TA (NO contact) opening button input.
19
TC (NO contact) closing button input.
20
TAL (NO contact) limited opening button input.
21
TD (NO contact) dynamic button input.
22
CMN common for all inputs and outputs.
23
TB (NC contact) stop button input (The opening of this contact interrupts the
cycle until a new movement command is given).
24
CSP (NC contact) safety edge input. Opening this contact will provoke a travel
direction inversion during the closing stage and during the opening stage
25
FTCS (NC contact) The opening of this contact will block all movement, until
the obstruction has been removed and the pause time has elapsed, due to
the safety device cutting in, the door will then continue moving in the closing
direction (only with automatic reclosing enabled).
26
FTCI (NC contact) safety and control devices in input (photocells invert the
travel direction when an obstruction is detected). Opening this contact will
provoke a travel direction inversion during closure due to the cutting in of the
safety device.
27
EMRG2 (NO) emergency manoeuvre input 2.
28
EMRG1 (NO) emergency manoeuvre input 1.
29
CMN common for the emergency buttons.
30
Inner conductor for radio receiver antenna (if an external antenna is fitted use
a coaxial type cable RG58 with an impedance of 50 ).
31
Outer conductor for radio receiver antenna.
10
J1
F3
L3
J2
10
Collegamento motori/encoder a 4 fili
Connecting motor/4-wire encoder
Branchement moteur/encodeur à 4 fils
Anschluss der Motor/Encoder mit 4 Drähten
Conexionado motores/encoder de 4 conductores
COLORE
CABLAGGI
Bl
Blu
Gr
Verde
Gy
Grigio
Yw
Giallo
KABELFARBEN
Bl
Blau
Gr
Grün
Gy
Grau
Yw
Gelb
ENCODER 1
M1
Bl
Gr
1
2
3
4
B1
via radio
CSER Serial connection (only for diagnostics)
D1
Six-segment LED display
DS1
Selection dip-switch
(6)
F1
10A blade fuse
(motor power protection)
(6)
F2
10A blade fuse
(motor protection during battery operation)
(6)
F3
4A
blade fuse
(24V circuit protection)
F4
4A
blade fuse
(6)
(24V circuit protection during battery operation)
F5
4A
blade fuse
(6)
(electric lock protection)
J1
Battery connection
J5
(1)
.
(1)
.
4A
F2
F4
L2
L1
F1
COLOUR CODE COLORATION
CODE
DES CÂBLAGES
Blue
Bleu
Green
Vert
Grey
Gris
Yellow
Jaune
COLORACIÓN
CABLEADOS
Azul
Verde
Gris
F5
Amarillo
ENCODER 2
M2
Bl
Gr
Gy
Yw
Gy
Yw
5
6
1
2
3
4
5
6
(1)
Note
The total of the 2 external device outputs must not exceed 10 W.
Note
(2)
J6
- in position 1 the safety edge with NC contact is selected;
- in position 2 the safety edge with 8.2 k contact is selected;
If you bridge the CSP
ALL UNUSED NC CONTACTS MUST BE JUMPED and consequently the security
device test must also be deactivated (FTCI , FTCS
If you want to activate the FTCI, FTCS test both the transmission and receiver parts
Vdc
transmission and movement of the gate/s.
Switch on the power and make sure that the indicator LEDs are in the following
condition.
-
L1
Power on
-
L2
Battery charging
-
L3
Wrong battery connection
-
L4
Transmitter code programming indicator
-
L5
-
L6
-
L7
-
L8
(2)
.
-
L9
-
L10
-
L11
-
L12
Note
(3)
(4)
Note
Note
(5)
Check that the activation of the safety devices switches the corresponding
LEDs off.
If the green power on LED "L1" doesn't light up check the condition of the fuses
and the power cable connection at the transformer primary.
If one or more of the safety LEDs do not light up check the contacts of the
relative security devices and check that the unused safety device contacts have
been bridged.
J3
L5
L6
J4
L7
J5
DS1
TD
RA
PLP
1 2
P2
3
LP
LS
Pos.1 Pos.2
FTCI
L4
TFTI
TFTS
SAP
P3
ELS
LC/CH2
7
8
9
10
11
12
13
14
15
J2
Transformer secondary protection
J3
Enable transmitter memorisation via radio
J4
Radio channel selection
J5
Binding posts 9, 10 selection (courtesy light/CH2 via radio)
J6
Safety edge selection CSP NC/8.2 k
MM
Transmitter code memory module
P1
Programming button (PROG)
P2
Transmitter code memorization button (MEMO)
P3
Transmitter code cancellation button (DEL)
R1
Radio frequency module, 433 MHz for S449 transmitters
Note
(6)
: These are automotive type blade fuses (max. voltage 58 V)
19
J6
TB
FTCI
FTCS
CSP"
TA
TC
TAL
TD/CH1
ON
ON
R1
B1
MM
L9
L8
L11
D1
L10
L12
CSER
1 2
3
J6
1 2
1 2
3
3
Pos.1 Pos.2
21
24
16
17
18
19
20
22
23
1 (NC).
OFF
CTRL 30
ON
OFF
(3)
(4)
OFF
OFF
ON
(5)
(5)
ON
ON
(5)
ON
(5)
OFF
OFF
OFF
OFF
CS 1283
DC 0406
P1
CMN
EMRG 1
EMRG 2
25
26

Advertisement

Table of Contents
loading

Table of Contents