Step 4. Select v, then t to change the display to text mode:
Display Mode Configuration:
Current -> K - Keyword mode
Enter new value, or [Q] to Quit:
T
Step 5. To decode the blinking state of System LED, review the entire SEL and look at events with alert
level 3 and above.
For example:
Log Entry 24: 14 Feb 2003 15:27:02
Alert Level 3: Warning
Keyword: Type-02 1b0800 1771520
Hot Swap Cage: SCSI cable removed
Logged by: BMC;
Data1: Device Removed/Device Absent
0x203E4D0AC6020220 FFFF0008F61B0300
Log Entry 73: 00:00:12
Alert Level 3: Warning
Keyword: Type-02 050301 328449
The server's built-in sensors have detected an open chassis door.
Logged by: BMC;
Data1: State Asserted
0x200000000C020570 FFFF010302050300