Parameter
Description
This parameter allows the user
F1 PCt
to enter the Percent weighing
Function. See Section 10.7.
F2 LLk
This parameter prevents the
normal user from changing the
limits with the help of a Limit
Lock.
This parameter sets the LED
F3 LEd
indicator to off or on and the
LED type (whether LED's are
on in the form of a continuous
bar or a spot LED).
This
F4 bEP
Beeper to off or on. If set to
on, the beeper can further be
set
weighing result is within or
outside
limits.
This parameter allows setting
F5 CPS
of a new Check weighing
password, must be entered
twice
complete, it will display "
F6 nCK
This
negative
function with ability to do
negative tare.
NOTE:
1.
The Check weighing password is separate from the scale password,
see section 13.3.
2.
If the password is other than 0000, user must enter the password to
gain access to "F2 LLk", "F3 LEd", "F4 bEP", "F5 CPS" and "F6 nCK
© Adam Equipment Company 2007
BALANCES.COM
parameter
sets
to
sound
when
the
check-weighing
when
asked.
When
donE
parameter
enables
check
weighing
Options
None
With LLK set to Off (
the user is allowed to
change limits at any time.
With LLK set to Preset
PSt
(
), the user is allowed
to use one of the preset
limits only.
bAr
- Bar type
Spot
- Spot type
oFF
- Off
the
bP oFF
- Off
bP inL
- Within limits
bP otL
- Outside limits
the
(>20d)
To be entered manually.
".
on
oFF
25
Default
setting
Enabled
always
oFF
oFF
),
bAr
bP inL
0000
on
".