3. Select the Region from the drop-down list for detection settings.
4. Click Area Settings and click Draw Area button to start the area drawing.
5. Click on the live video to specify the four vertexes of the detection region, and
right click to complete drawing.
6. Set the time threshold and detection sensitivity for object removal detection.
Threshold: Range [5-20s], the threshold for the time of the objects removed from
the region. If you set the value as 10, alarm is triggered after the object disappears
from the region for 10s.
Sensitivity: Range [1-100]. The value of the sensitivity defines the similarity
degree of the background image. Usually, when the sensitivity is high, a very
small object taken from the region can trigger the alarm.
7. Repeat the above steps to configure other regions. Up to 4 regions can be set. You
can click the Clear button to clear all pre-defined regions.
8. Click Arming Schedule to set the arming schedule.
9. Click Linkage Method to select the linkage methods.
10. Click Save to save the settings.

10.3 VCA Configuration

10.3.1 Behavior Analysis

The behavior analysis detects a series of suspicious behavior, and certain linkage
methods will be enabled if the alarm is triggered.