Vca Configuration; Behavior Detection - HIKVISION DeepinView DS-2CD6425G0/F Series User Manual

Table of Contents

Advertisement

disappears from the region for 10s.
9. Drag the slider to set the sensitivity value.
Sensitivity: Range [1-100]. It stands for the percentage of the body part of an
acceptable target that leaves the pre-defined region.
Sensitivity = 100 – S
S
stands for the target body part that leaves the pre-defined region. S
1
the complete target body.
Example: if you set the value as 60, a target is possible to be counted as a
removed object only when 40 percent body part of the target leaves the region.
Note:
The Sensitivity of the detection is supported by certain models. Refer to
actual display for details.
10. Repeat the above steps to configure other regions. Up to 4 regions can be set. You
can click the Clear button to clear all pre-defined regions.
11. Click Arming Schedule to set the arming schedule.
12. Click Linkage Method to select the linkage methods.
13. Click Save to save the settings.

VCA Configuration

Behavior Detection

The function detects a series of suspicious behavior, and certain linkage methods will
be enabled if the alarm is triggered.
Network Camera User Manual
/S
*100
1
T
140
stands for
T

Advertisement

Table of Contents
loading

Table of Contents