5.3.2 RS-232C Interface (OKI Standard Type)

1
Interface signals
A25013.doc
Pin No.
Signal
1
Protective ground
2
Transmitted Data
3
Received Data
4
Request to Send
6
Data Set Ready
(Note 2)
7
Signal Ground
20
Data Terminal Ready
5,8 to 10,11,
-
12 to 19, 21
to 24
25
Initial
(Note 2)
Note 1 Connector pin arrangement
OP425_06.eps
13
25
(View from the cable side)
Note 2 The enabled or disabled state of the initial state request signals assigned to pins 6 and 25 is selectable with the DIP
SW1-1 and DIP SW1-2.
|
OKIPOS 425D
66
Code
Signal
Function
PG
-
Frame ground
TD
From printer
Data from printer
RD
To printer
Data to printer
RTS
From printer
Indicates printer cannot receive
data in printer and Customer
Display Busy/Ready protocol
DSR
To printer
Indicates that data can be sent
SG
-
Signal ground
DTR
From Printer
Indicates printer cannot receive
data in printer Busy/Ready
protocol
-
-
Unused
INIT
To Printer
Requests printer reset