Sledfaultled; Smartdata; Temperature; Virtualdriveinfo - ATTO Technology Diamond Storage Array S-Class Installation And Operating Manual

Diamond storage array s-class
Table of Contents

Advertisement

SledFaultLED

Changes the state of the selected sled LED to the
indicated state. Enter sled number (1-12) (all)
Default: off
Set syntax: set SledFaultLED
[all|1|2|3|4|5|6|7|8|9|10|11|12] [on| off]|

SMARTData

Displays the current SMART Data (Self-Monitoring
Analysis and Reporting Technology) for the specified
drive.
Immediate command: SMARTData [Sled#] [Drive#]

Temperature

Returns the current internal temperature of this Diamond
Storage Array in degrees Celsius. The value is read only.
Get syntax: get Temperature

VirtualDriveInfo

Displays the named Virtual Drive definitions.
Immediate command: VirtualDriveInfo [active | planned]
[Virtual Drive ID]
Diagnostic CLI commands