Operation - Panasonic KX-TDE600 Installation Manual

Pure ip-pbx
Hide thumbs Also See for KX-TDE600:
Table of Contents

Advertisement

5.1.3 Operation

5.1.3 Operation
PROBLEM
Cannot set the IP
address, subnet mask
address, and PBX IP
address to the IP-PT.
Cannot register the
IP-PT.
The IP-PT cannot
connect to the PBX.
Whenever you try to
make calls using a SIP
Extension, a busy tone
is heard.
When using the
speakerphone on an
APT, nothing is audible.
When using the
speakerphone/monitor
mode with a DPT,
nothing is audible.
The PT does not ring.
244
Installation Manual
PROBABLE CAUSE
An unusable value is
being set.
The necessary network
parameters are not set
to the IP-PT.
The wrong IP address,
subnet mask address,
PBX IP address, or
default gateway
address was entered.
The Ethernet cable is
not connected
correctly.
The DHCP server is not
active.
The status of the port
that the SIP Extension
is connected to is Out of
Service.
The HANDSET/
HEADSET selector is
set to the "HEADSET"
position.
The "HEADSET" mode
is selected by Personal
Programming,
"Handset/Headset
Selection".
The ringer volume is off.
SOLUTION
Set an IP address within the valid range.
IP address of the IP-PT/PBX: "1.0.0.0" to
"223.255.255.255" Subnet mask address:
"0–255.0–255.0–255.0–255" (except
0.0.0.0 and 255.255.255.255)
When not using a DHCP server, set the IP
address, subnet mask address, and enter
the PBX IP address. If necessary, also
enter the IP address of the default
gateway.
When using a DHCP server, enter the
PBX IP address.
Check each parameter and enter the
correct value.
Check the Ethernet cable connections.
Restart the DHCP server.
Disable DHCP and re-enter settings as
appropriate.
Change the port status from Out of
Service to In Service using the
Maintenance Console.
When the headset is not used, set the
HANDSET/HEADSET selector to the
"HANDSET" position.
When the headset is not used, select the
"HANDSET" mode by Personal
Programming.
Turn on the ringer volume.

Advertisement

Table of Contents
loading

Table of Contents