Heronhill - for all your Toshiba requirements
Precautions
Avoid installing the outdoor unit in the following locations:
!
Where there is danger of flammable gas leakages.
!
Where there are high concentrations of oil.
Where the atmosphere contains an excess of salt (as in coastal areas).
!
The air conditioner is prone to failure when used under this condition unless special maintenance
is provided.
!
Where the airflow from the outdoor unit may cause annoyance.
!
Where the operating noise of the outdoor unit may cause annoyance.
!
Where the foundation is not strong enough to fully withstand the weight of the outdoor unit.
!
Where the water drainage may cause a nuisance or a hazard when frozen.
Where strong winds may blow against the air outlet of the outdoor unit.
(The high pressure switch could be tripped if a strong wind should blow against the air outlet
!
during cooling operation). Where this condition is likely to be present, protect the outdoor unit
against winds, for example by:
1
Installing the outdoor unit in parallel with the building so that it can be protected by other buildings:
Strong wind
2
Installing the outdoor unit with the air outlet facing the wall, such as on an exposed rooftop:
Wall
Tel: 01823 665660
O
U
L
UTDOOR
NIT
OCATION
~ 5 ~
www.heronhill.co.uk
Building
Strong
Rooftop
Fax: 01823 665807
GB