* Before removing the projection lens, set the IRIS setting to "High Contrast". (See page 25.)
1. Removing the lamp door and the lamp unit
1-1. Loosen the lamp door fixing screw, slide the lamp door in allow direction and lift off the lamp door.
1-2. Loosen 2 lamp unit fixing screws and lift off the lamp unit.
2. Removing the top body
2-1. Insert a postcard or such thick paper under the lens barrel and between the body.
2-2. Remove 6 fixing screws for the top and bottom bodies.
2-3. Remove the fixing screw for the top body (terminal side).
2-4. Press and hold the areas (marked with *) and disengage the claws on the top body to remove the top body.
2-5. Draw out the postcard.
2-1
Short neighborhood
(10 cm)
Long neighborhood
(15 cm)
Thick paper such as postcard

REMOVING OF MAJOR PARTS

Lamp Unit
1-1
To protect the lens barrel
against scratches
1-2
Lamp Door
Top Body
2-4
Bottom Body
17
EIP-3500
2-3
2-2
2-5