Download Print this page

SELVA MARINE DOLPHIN 9.9 Service Manual page 380

Advertisement

ELEC
CHARGING SYSTEM
SERVICE POINTS
CHARGING SYSTEM PEAK VOLTAGE
1. Measure:
9 Rectifier-regulator output peak volt-
age
Excessively over specification →
Replace.
Excessively below specification →
Check the lighting coil.
6 A model
Output peak voltage:
Cranking
r/min
+
V
6.0
+: Circuit
* : Loaded
10 A model
Output peak voltage:
Cranking
r/min
+
V
6.0
+: Circuit
* : Loaded
2. Measure:
9 Lighting coil output peak voltage
Below specification → Replace.
6 A model
Output peak voltage:
Cranking
r/min
+
V
6.5
+: Circuit
* : Loaded
8-29
R-B
1,500
3,500
+
*
*
20
46
R-B
1,500
3,500
+
*
*
20
46
G-G
1,500
3,500
+
*
*
6.0
21
46
E