Firebox Installation - Quadra-Fire 57ST-ACC-AU Installation And Operating Instructions Manual

5700 step top acc wood burner
Hide thumbs Also See for 57ST-ACC-AU:
Table of Contents

Advertisement

CORNER POSITIONING (45°)
CORNER POSITIONING (45°)
Fig. 4
Table 2
A
Min. clearance from fi rebox to corner walls
B
Depth of fl oor protector
C
Min. distance from fi rebox opening to fl oor protector front
D
Min. distance from fi rebox to fl oor protector side
E
Width of fl oor protector
Minimum fl oor protector thickness
1. If a separate fl oor protector is being used position now. Place the fi rebox on a fl oor protector that
is at least 6mm thick to suit the minimum installation clearances. (See Fig 3 or 4).
2. Seismically restrain the fi rebox and the fl oor protector to the fl oor.
3. Fit 2 x 6mm fi xings suitable for the fl oor material. DO NOT over tighten.
4. Fit timber trim pedestal edging to front and back of base (optional).
October 12, 2015
A
A
D
Drawing not to scale
DESCRIPTION
Hawkwind Kit
Shall be Fitted

FIREBOX INSTALLATION

7038-201D
5700 Step Top ACC Wood Burner
B
C
E
100mm
1210mm
450mm
76mm
850mm
6mm
Page 5