Configuring the system monitor

Contents

System monitor cabling

Multi-column systems
Communication Server 1000M and Meridian 1
This section contains information on the following topics:
System monitor cabling. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Configuring the System Monitor. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Cabling the System Monitor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Alarm interfacing to Candeo . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Configuring the alarm ports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Customizing alarms. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Cabling between system monitors in a multi-column system requires the use
of a single cable. The cabling is done in a daisy-chain fashion with the master
system monitor at the beginning of the chain. The address of each slave
system monitor must be unique and there cannot be any gaps in the slave
numbering. Figure 62 shows a typical cabling scheme between columns.
Large System Installation and Commissioning
Page 151 of 456
151