Equipping Rules; Oc-48 Protection Switching - Nortel NTRN10AN Planning Manual

Nortel network multiservice platform user's guide
Table of Contents

Advertisement

3-70 Hardware feature descriptions
Alarm LED definitions
The following table lists the OC-48 STS interface circuit pack LEDs.
LED
Status (top)
Status (bottom)

Equipping rules

The OC-48 STS optical interface circuit pack can be installed in slots 3
through 12. See

OC-48 protection switching

OC-48 traffic can be protected by 1+1 linear, or UPSR protection.
1+1 linear protection
OC-48 linear protection switching is 1+1 non-revertive, unidirectional or
bidirectional. If a fiber cut occurs in either the receive or transmit fibers of the
active fiber path, or the transmitter or receiver OC-48 optical interface circuit
pack fails at either end of the active fiber span, traffic is switched from the
active OC-48 transmitter or receiver to the standby OC-48 transmitter or
receiver. Switching can also take place under user control.
In bidirectional protection switching, if traffic in one of the two directions is
interrupted, traffic in both directions is switched to the protection line. In
unidirectional protection switching, if traffic in one of the two directions is
interrupted, only the interrupted traffic switches to the protection line; traffic
in the uninterrupted direction remains on the working fiber. Both OC-48
interface circuit packs are active if f unidirectional switching occurs and one
fiber fails.
The signal degrade threshold is user-provisionable for the working OC-48
facility of a 1+1 linear protected OC-48 pair. The default value is 10
threshold is provisionable within the range 10
(BER) drops below the threshold, an autonomous protection switch occurs.
UPSR path protection
OC-48 path switching uses nonrevertive protection. There are no permanent
STS-1 STS-3c, STS-12, STS-12c, STS24c or STS-48c protection or working
paths. The network element receives two incoming STS-1, STS-3c, STS-12,
OPTera Metro 3500 Multiservice Platform
Color
Red
Yellow
Green
Table 3-3 on page 3-6
Note 1: Requires the shelf to be equipped with STX-192 circuit packs in
slots 13 and 14.
Note 2: Supports STS managed connections only.
NTRN10AN
Description
Circuit pack failure
Loss of signal
In service and carrying traffic
for operational temperature ranges.
-5
to 10
Rel 12.1 Standard Iss 1 Apr 2004
-6
. The
-9
. If the bit error rate