2-110 Operation, administration, and maintenance (OAM) features
Table 2-24 (continued)
DS1 performance monitoring - supported parameters for DS3VTx12
PM parameter
UASP Near End Tx
UASP Far End Tx
Note: DS3/VTx12 circuit pack is not supported on shelves equipped with STX-192 circuit
packs.

Retrieving performance monitoring counts

OPTera Metro 3500 Release 11.0 introduced enhancements for retrieving
performance monitoring (PM) counts.
PM retrieval uses a continuation message mechanism, as described below.
OPTera Metro 3500 Multiservice Platform
A faster retrieval method is used to retrieve PM counts for DS1 service
module (DSM) facilities and for protected DS1 facilities.
Note: DSM facilities include DS1, OC-3, and STS-1 facilities that carry
traffic on a DSM.
A continuation message mechanism is implemented in the response block
for RTRV-PM TL1 commands.
A TL1 response is displayed within two minutes after you issue a
RTRV-PM command.
If no PM data is available within 2 minutes, a continuation message is sent
to the TL1 session. The continuation message is sent at regular intervals (1
minute and 40 second intervals), until PM data is available. The
continuation message mechanism indicates that additional time is required
for reporting PM data and prevents the MOA or Site Manager from timing
out.
Note: The MOA or Site Manager times out if no response is received in
two minutes.
If partial or complete PM data is available in under two minutes, it is
reported to the TL1 session. The termination character in the response
message indicates whether the data is incomplete or complete (see
2-25).
When all PM data has been reported, the termination character in the last
response indicates that the process is complete.
Note: A time change on the network element does not affect the operation
of the continuation message timer.