Installing The R2Mfc Mbm - Nortel R2MFC Installation And Configuration Manual

Media bay module
Table of Contents

Advertisement

Chapter 4

Installing the R2MFC MBM

This chapters describes how to install and remove an R2MFC MBM in a host BCM system.
This chapter provides the following installation and removal procedures:
"Shutting down the system"
"Installing an R2MFC MBM" on page 34
"Removing an R2MFC MBM" on page 38
"Wiring an R2MFC MBM" on page 41
Figure 7
provides an overview of the steps for installing the R2MFC MBM.
Figure 7 Overview of the R2MFC MBM installation
Set module DIP
switches
Shut down the BCM
Disconnect cables and
power from both units
Remove front bezel
from the expansion unit
to eject blank filler on
MBM
Install new module
Replace bezel
Restore power to BCM
and expansion unit
Reconnect all cables
Monitor LEDs for power
and status
R2MFC Media Bay Module Installation and Configuration Guide
Is this
NO
installation part
of a new system
installation?
Use Element Manager
or Unified Manager
to identify the module
to the system
Continue with
initialization