Samsung DMT300 Series Service Manual page 49

Hide thumbs Also See for DMT300 Series:
Table of Contents

Advertisement

Error type
Error mode
Error type
Error mode
LED or Input
None
Key Fail
Copyright© 1995-2010 SAMSUNG. All rights reserved.
Checking Method
6) Check the operation of the dispenser.
If rinse aids are not dispensed, a dry error may occur.
Because the dishes are heated and heat dried during the last
drying cycle, the dried state of plastic dishes may not be optimal.
Checking Method
1) Check the connections for the Sub PBA connector
2) Check the LED and Input Key
1) Push 'Normal' + 'Heavy' + 'Power Key'
2) Push 'Normal' Key 4 times
3) Push all key except Start/Pause Key.
Normal : All LED is light.
3) Check the DC voltage of the Main PBA.
Corrective actions
See "Detergent is not dispensed"
Corrective actions
Reconnect the Sub PBA connectors.
Faulty : Replace the Sub PBA.
See "Main PBA DC voltage error".
4. Troubleshooting
4-20

Hide quick links: