4. Troubleshooting
Error Type
Error mode
4-5
Checking Method
5) Check whether the coil in Inlet Valve is conductive (Remove the
connector before measuring.)
Normal: Approx. 1.2 kΩ
6) Check whether the Inlet Valve is operating normally.
Check the operation of the Inlet Valve
Normal: 120V
Check the Inlet Valve Relay.
: Check the voltage between the white wire of the Main PBA CN101
connector and the brown wire of the CN201
Normal: 120V (while operating)
7) Check the Power Relay.
8) Check whether the water supply stops after water is supplied for 5
seconds.
9) Check whether the water supply stops after water is supplied for 1 or
5 minutes.
Corrective actions
Faulty: Replace the Inlet Valve.
Faulty: Replace the Main PBA assy.
Normal: Replace the Inlet Valve
Remove Retainer.
Check voltage.
See the "Power Relay error".
Replace the Flow Meter.
Check the water supply valve and increase the water pressure.