3. Disassembly and Reassembly
3. Remove the drain hose from the bracket hose drain.
Hold the drain hose using both hands and move it up
and pull it out.
4. Use your hand to hold the case brake and rotate the
cover brake. Use a jig to remove by rotating the cover
brake. If you have no jig, you can use a pair of long
nose pliers.
It can be separated into a gasket brake, cover brake and
case brake.
5. Remove the case sensor assy from the case brake assy.
Be careful to avoid breaking them, because they are
connected with a hook.
3.2.11. Inlet Valve & Flow Meter
1. Place the dishwasher on its back and remove two (2)
screws on both sides of the cover front lower.
Remove the cover front lower.
3-17
6. Separate the case sensor assy into the case sensor and
the cover sensor assy.
Be careful to avoid breaking them, because they are
connected with a hook.
7. Remove the pole sensor from the cover sensor assy.
8. Remove the micro switch which is fixed by a hook of
the cover sensor assy.
Disconnect the micro switch connector.