Samsung DMT300 Series Service Manual page 44

Hide thumbs Also See for DMT300 Series:
Table of Contents

Advertisement

4. Troubleshooting
Error type
Error mode
Main PBA
None
DC voltage
error
4-15
Checking Method
2) Check the operation of the Door Sensing Switch.
(Remove the connector before measuring.)
: Check the blue wire and the switch connected to the blue wire.
Normal: OPEN (when the door is open)
Normal: SHORT (when the door is closed)
Check the DC voltage of the Main PBA.
Measure the voltage between pin 6 (amber) of the main PBA CN7
connector and pin 7 (pink) of the CN7 connector.
Normal: 4.5V to 5.5V
Measure the voltage between pin 6 (amber) of the main PBA CN7
connector and pin 9 (white) of the CN7 connector.
Normal: 10.5V to 13.0V
New PBA
Check the DC voltage of the Main PBA.
Measure the voltage between pin 6 (amber) of the main PBA CN302
connector and pin 7 (pink) of the CN302 connector.
Normal: 4.5V to 5.5V
Measure the voltage between pin 6 (amber) of the main PBA CN302
connector and pin 9 (white) of the CN302 connector.
Normal: 9.5V to 13.0V
Corrective actions
Faulty: Replace the Door Sensing Switch.
Normal: Replace the Main PBA assy.
Faulty: Replace the Main PBA assy.
Copyright© 1995-2010 SAMSUNG. All rights reserved.